Here are a few easily implemented free or low expenditure (financial) suggestions that can improve the overall security status for all wiring closets and cables.

Eliminate Public Access to Wiring Closets and Cables - Wherever possible locate all wiring closets in locations that are not accessible to the public.

Limit Insider Access to Wiring Closets and Cables - Try to ensure that general insider access to wiring closets is restricted to “the few” (the IT team).

Naming Wiring Closets and Cables - Ensure that you build naming conventions that include wiring closets and cables. An earlier article entitled “Building Your Own Naming Conventions” explains how to do this. Click this link to go there Building Your Own Naming Convention.

Securing Wiring Closets and Cables Labeling Systems - Now to apply labels to your wiring closets and the cables inside them. For more information about developing and implementing, your very own highly secure labels click this link Making Your Own Indexed Labeling System.

Partitioning the Wiring Closet- When multiple utilities must share the same wiring closet then it is a good idea to partition the available space in your wiring closet. The basic idea here is that each utility will have its own dedicated and locked wiring closet partition.

Dedicated Wiring Closet Compartments - Thus, electrical wiring will use its own dedicated self-contained compartment in the wiring closet if need be. Other utilities, including IT infrastructure and components will have their own dedicated compartments as well.

Reducing Electro-Magnetic Interference (EMI) - For the IT related wiring closet partitions, I strongly recommend that the different cabling types have their own compartments as well. This will help to reduce the negative impacts of EMI (noise/cross talk) from external sources.

Wiring Closet Cable Bundling and Grouping - With multiple types of IT cable to be found in wiring closets it is essential to subdivide these cables into groups of related cable types, functionality and the services that each cable transports. Use cable ties to keep the individual member cables of a custom group together.

Destination and Services - One practical grouping system would be to bundle all cables heading to the same destination together. Another would be to bundle wiring closet cables involved in the delivery of the same specific services together.

Dedicated and Exclusive Fiber Optic Cabling Compartments - Although fiber optic cables are “immune” to EMI they still require careful planning, management and maintenance. Accidental damage to a very small number of the individual fiber optic lines within a fiber optic cable often necessitates the replacement of the entire cable. I can tell you from experience that this is no fun.

Cable Conduit - Using conduit to encase cabling will add an additional layer of physical protection for cable runs is a smart move.

  • When using conduit for cable runs always ensure that there is ample room inside the conduit for all cabling you wish to run through it
  • Do not squeeze cable into conduit
  • Leaving space in the conduit will help to reduce the amount of “inside the conduit” cross talk that your cabling will experience

Regulatory Compliance - Always check to ascertain what if any regulatory compliance aspects pertain to your network specifically. You may need to employ the services of a duly qualified and registered cable technician.

Network Backbone - All network backbone cabling (fiber optic and copper) should have their own dedicated wiring closet compartments.

  • Building-to-building network backbone fiber optic cable runs should be in fiber optic backbone only wiring closet compartments
  • If traversing open spaces then it is a good idea to bury these fiber optic backbone links

Locks - Wiring closet locks need to be robust and tamper proof. When the wiring closet contains multiple internal compartments, each compartment must have its own discrete locking mechanisms.

Auto Locks - Here is a group of locking devices that will automatically lock immediately upon engagement of the locking elements.

  • You do not need a key to lock them
  • You do need a key to reopen them
  • This type of lock comes in both the normal physical lock variety, the electronic variety and as combination locking mechanisms that employ multiple strategies

Keys - Implementing a secure locking system with appropriate lock and control mechanisms and policies will fall flat on its face if you do not take the same due care and attention with respect to the keys and keying mechanisms.

Master Keys - I think you will already be familiar with the concept of one key that will open many locks. I have implemented the use of “master keys” successfully on many occasions myself.

  • Because we had deployed fully self-contained internal wiring closet compartments, we are able to let the electrician into the wiring closet using a master key and keypad combination to regulate entry into our wiring closets
  • The electrician can do his job without ever needing to expose every other wire and cable also contained in any given wiring closet
  • All of the key mechanisms to open the individual compartments inside use different key mechanisms and types
  • In our case, not only are we using master key and keypad combinations to regulate external access to the contents of the wiring closet, we are doing likewise for the interior dedicated compartments as well
Page 1 of 2 | Prev 12Next»
7
Liked It
I Like It!
Related Articles
Wiring Closet and Cabling  |  Wireless Networking Physical Security
More Articles by TechDoc
Wireless Networking Physical Security  |  Wireless Networking Security Considerations
Latest Articles in Security
Make Strong Passwords  |  Five Extremely Useful Password Recovery Programs
Comments (1)
#1 by jasmine, May 26, 2008
i like this post great job

jasmine celion
cool-hotstuff.blogspot.com

Post Your Comment:
Name:  
Copy the code into this box:  
Inside Computersight

Communication & Networks

 /

Computers

 /

Hardware

 /

Operating Systems

 /

Programming

 /

Software


Popular Tags
Popular Writers
Computersight
About Us
Terms of Use
Privacy Policy
Services
Submit an Article
Advertise with Us
Contact

© 2007 Copyright Stanza Ltd. All Rights Reserved.